    adic scalar i500 user manual

    Quantum Corporate Headquarters To order documentation on the Scalar i500 or other products contact: Quantum Corporation P.O. Box 57100 Irvine, CA 92619-7100 (949) 856-7800. You can also access software, firmware, and drivers through this site. For further assistance, or if training is desired, contact Quantum: Global Call Handling For additional contact information:. Its Capacity on Demand (COD) scalability lets it grow non-disruptively with users’ data. And the Scalar i500 is designed to integrate easily with disk backup, making it the perfect library for next-generation backup architectures. All power is derived from the control module. The paragraphs following Figure 5 describe the components in detail.For more information on the library user interfaces, see Chapter 2, Understanding the User Turning off the front power switch turns off the robot and operator panel, but power still runs to the power supplies. In the event of danger to personnel or property, immediately turn off the rear power switch and remove all power cords. The robotic arm (picker) has picker fingers that enable it to grab tape cartridges and move them into positions along X, Y, and Z motion coordinates. The robotic system and the barcode scanner work together to identify the locations of resources within the library. Please see Supported Components and media supported by the Scalar i500 library. The library supports mixing different tape drive types within the library and within partitions. For information on how to do this, see With Partitions on page 61. This section describes several features of Scalar i500 libraries. The operator panel is located on the front door of the control module and allows you to work locally on the library via the user interface. The web client allows you to view and perform library functions from remote sites and is accessible through a browser. Scalar i500 tape libraries support WORM (write once, read many) technology in LTO-3 and LTO-4 tape drives.

    • adic scalar i500 user manual pdf, adic scalar i500 user manual download, adic scalar i500 user manual free, adic scalar i500 user manual 2017, quantum scalar i500 user manual, quantum scalar i500 service manual, quantum scalar i500 user guide, adic scalar i500 manual, adic scalar i500 user manual, quantum scalar i500 user manual, quantum scalar i500 service manual, quantum scalar i500 user guide, adic scalar i500 manual, adic scalar i500 user manual, adic scalar i500 user manual pdf, adic scalar i500 user manual download, adic scalar i500 user manual free, adic scalar i500 user manual 2017.

    With multi-tier storage, teams can better harness their data and transform the world. Tape Library Expands up to 2.6PB Windows Server 2012 R2 Device Driver for Scalar i500 Tape Library Windows Server 2016 Device Driver for Scalar i500 Tape Library Windows Server 2019 Device Driver for Scalar i500 Tape Library IBM Device Driver for AIX version 13.0.5.0 for Scalar i500 Tape Library SNAPI Client Plug-in 2.0.1 Version 120i.GE004. The SNAPI Client Plug-in for Scalar i500. Refer to the Scalar i500 User's Guide for additional information. Select the link(s) of the library or drive firmware you want below to download. Only customers with active Warranty or Service Maintenance contracts will be able to access the content. If your library firmware is older than 400G please call Tech Support for assistance. Failure to follow the instructions may interrupt the upgrade process and may cause the System to be unresponsive or to require repair. Select the link(s) of the library or drive firmware you want below to download. Only customers with active Warranty or Service Maintenance contracts will be able to access the content. If your library firmware is older than 400G please call Tech Support for assistance. Failure to follow the instructions may interrupt the upgrade process and may cause the System to be unresponsive or to require repair. Channel Zoning Quantum Corporation may revise this publication from time to time without notice. Channel Zoning. 110 Configuring Host Mapping. 111 Configuring FC Host Port Failover. 113 Repairing and Enabling a Failed Target Port. Any other application is not considered the intended use. Quantum will not be held liable for damage arising from unauthorized use of the product. The user assumes all risk in this aspect. Scalar i500 User’s Guide. Please manage the lamp according to local, state, or federal laws. For more information, contact the Electronic Scalar i500 User’s Guide. Instead, it should be.

    Once you have configured network settings on the operator panel, you can log on to the library’s web client. After applying any of the settings on the Network Management screens, verify the settings on the Security Settings screen. When DHCP is enabled, the library obtains DHCP an IP address automatically. Your current web client browser session might become invalid, requiring you to close your current browser session. Access the web client using the new network configuration settings and log in again. After enabling SSL settings, use that library name to access the library. The SNMP MIB is also available on the Scalar i500 Note: Documentation and Training CD. You cannot download the SNMP MIB from the operator panel.For more information, Modifying Partitions on page 66 and When you manually create partitions, the library creates control paths. Working With Control Paths default control paths and how to change them. You can also access the screens directly on the operator panel and web client.You can access the screen, but you cannot apply changes while another administrative user is performing the same operation. A unique loop ID is selected by default for all FC tape drives installed in the library. For example, the tape drive installed in the top drive bay of a control module is assigned a default loop ID of 61. The library automatically assigns control paths when you set up partitions. You can modify the control path at any time. In the event that the control path connection to the host application fails, you can select a new control path for the partition. The license key certificate contains an authorization code that enables you to retrieve your license key from the Quantum web site. Once you install the license key on the library, the feature becomes available. In some cases, factory installed license keys will not be listed on the Web site and you will need to contact Quantum for a replacement.

    WORM allows non- rewriteable and non-erasable data to be written and provides extra data security by prohibiting accidental data erasure. The number of available pre-activated slots begins at 41 for all library configurations and increases in 46-slot increments to a maximum of 409 slots in the 41U library configuration. These keys are used by the IBM LTO-4 tape drive to encrypt information being written to, and decrypt information being read from, tape media. Q-EKM is installed on a server or servers. If you purchase Q-EKM for a particular size library and later expand the library, you must purchase an additional Q-EKM license at that time. Your new license key contains the entire license corresponding to your expanded library size. Operations on the library can be performed locally on the control module using the operator panel or remotely on your computer using the web client. These buttons provide quick access to information about the “health”. You can also see which partitions are online (in the Storage Slots section). The current user’s login privileges determine the information that is displayed in the Capacity View. You will find the same navigation buttons on the Library View as on the Capacity View. The operator panel is physically attached to the front door of the control module. A Setup Wizard helps you get started configuring your library, and menu commands on both the operator panel and the web client allow you to reconfigure your library at any time. If you misplace the password for the default administrative Note: account, contact Quantum Technical Support. For contact information, see Getting More Information or Help The Setup Wizard is an aid to assist you with the initial configuration of the library. For the operator panel, the paths refer to the navigation tabs at the top of the home page. For the web client, the paths refer to the menus. Continue with the Setup Wizard screens.

    Channel Zoning These LUNs can be re-mapped to new LUNs for presentation via ports 1 and 2. Further, custom LUN maps can be simultaneously defined for individual hosts. See Mapping on page 107. Assign a new LUN number for the device. The operator panel host mapping configuration screens Note: show less information about each device; however, you still select the host and device(s) and configure the LUN number(s(.) This feature is disabled by default. You can configure the FC host port failover feature so that a “standby”. The default internal network address is 10.10.10.X The library’s internal network enables communication among library components. While rare, it is possible that the default addressing of the internal network could conflict with your network, potentially causing the library to become confused. When the setting is enabled, the library will assist with tape drive unload operations in the event that a tape drive is not unloaded by a host command. When. The brightness and contrast to the default settings. You cannot configure the display settings from the web client.Most of the library functions described here can be found on the The information in this chapter assumes you are using the web Note: client. A storage column is a group of slots arranged vertically in the library. Columns are represented by the second digit of a library coordinate. Doing this will avoid over-loading the library with cartridges. Performing Media Operations. For information, see page 138. For information, see Bulkloading on page 129. Follow the on-screen prompts, or see the library’s online Help for step-by-step procedures. The storage slot and tape drive must be assigned to the same partition. This topic focuses on using the library user interface, not the host application, to load tape drives. The storage slot and tape drive must be assigned to the same partition. This topic focuses on using the library user interface, not the host application, to unload tape drives.

    If you cannot retrieve your license keys or need assistance, contact Quantum. For contact information, see More Information or Help 2 Upon receipt of your order, Quantum will ship you a license key certificate containing your authorization code. Note: If you order more than 46 COD slots: COD licenses come in 46-slot increments. Exception: If the license was applied at the factory, the word “. Library-managed encryption is an optional, licensed feature that must be enabled from the Scalar i500 library in order to begin encrypting data using the LTO-4 tape drive encryption capabilities. See the Quantum Encryption Key Manager User’s Guide for information on setting the port number on the Q-EKM server. You cannot select individual tape drives for encryption; you must select an entire partition to be encrypted. If you encrypt a partition, all Q-EKM-supported tape drives in that partition are enabled for encryption. Keep this information current to expedite the Service process. IP addresses must be entered in dot notation (for example, 192.168.0.1) and cannot exceed 255. If you misplace the password for the default administrative account, contact Quantum Technical Support. For contact information, see Getting More Information or Help. The default administrative user account cannot be deleted.User password schemes must be encrypted using UNIX crypt. In addition, user names (uid) and passwords (userPassword) must be created using lowercase characters to be compatible with the library. This group is equivalent to the local user privilege level. Any member of this group can manage this library. See Privileges on page 44 for more information on user privilege levels. The following operations should not be performed. NTP allows you to synchronize the library date and time with other components in your IT infrastructure. Administrative users can either modify the date and time zone settings manually or configure NTP. There is no need to manually reset the clock for time changes.

    Otherwise, the guide pin may scratch the front doors of the module on which you are stacking. Squeeze the handle of the Y-rail release mechanism, lift it out of its locked position, and slide it downward as far as it will go. For details, see Replacing Power Supplies 6 Connect all power cords, network data cables, and module-to- module cables. Make sure the module terminators are installed at the top and bottom of the stack of modules. See Firmware on page 163 for information on upgrading firmware. 2 Remove all tape cartridges from the library using the import and export commands of the operator panel or web client. Thumbscrews (behind doors) Scalar i500 User’s Guide. Otherwise, the guide pin may scratch the front doors of the module beneath it. Before removing the control module’s bottom cover plate, Caution: the robot assembly must be parked as described in Preparing to Install an Additional Expansion Module above. Scalar i500 User’s Guide Adding Expansion Modules to an Existing Library cover plate cover plate Control Module Control Expansion Module Module. Otherwise, the guide pin may scratch the front doors of the module on which you are stacking it. Scalar i500 User’s Guide. Prepare to use the library as follows: 1 Add the tape drives to the modules. Make sure the module terminators are installed at the top and bottom of the stack of modules. For cabling instructions, see Cabling the Library on page 172. Before unstacking the library, the robot assembly must be placed in the control module.For details, see Adding, Removing, and Replacing Power Supplies on page 281. Squeeze the handle of the Y-rail release mechanism, lift it, and release it so that it locks into place. Scalar i500 User’s Guide. Otherwise, the guide pin may scratch the front doors of the module beneath it. Squeeze the handle of the Y-rail release mechanism, lift it out of its locked position, and slide it downward as far as it will go.

    For details, see Removing, and Replacing Tape Drives 3 Add the power supplies. For details, see Replacing Power Supplies 4 Add the LCB to the control module. Support the robot assembly by holding onto the Caution: broad metal X-axis plate. Make sure the module terminators are installed at the top and bottom of the stack of modules. Without tape drives, tape cartridges, or power supplies, a Warning: control module weighs approximately 58 lbs. An expansion module, without tape drives, tape cartridges, or power supplies, exceeds 65 lbs. The library will not be able to locate tape cartridges that Caution: are removed from one partition and returned to a different partition. The tape cartridges must be returned to the same partition they were removed from. Otherwise, the guide pin may scratch the front doors of the module beneath it. A small notch on the bottom of the control module aligns it with the top of the 9U expansion module. Squeeze the handle of the Y-rail release mechanism, lift it out of its locked position, and slide it downward as far as it will 11 Unpark the robot assembly. It will lower to the bottom module of the library. Parking tab in “unparked” position Scalar i500 User’s Guide. For details, see Removing, and Replacing Tape Drives 3 Add the power supplies. For details, see Replacing Power Supplies 4 Add the LCB to the control module. After the expansion module is removed, there may be more slots licensed than are available.An expansion module, without tape drives, tape cartridges, or power supplies, exceeds 65 lbs. The tapes must be returned to the same partition they were removed from. Since the. Before unstacking the modules, the robot assembly Caution: must be parked as described in the Expansion Module 2 Disengage the Y-rails so the modules can be unstacked safely. Squeeze the handle of the Y-rail release mechanism, lift it, and release it so that it locks into place. Scalar i500 User’s Guide.

    When the tape drive mode is online, the tape drive is available for use. When the tape drive mode is offline, the tape drive is offline to the host application and is not available for use. The library supports two methods for cleaning tape drives with cleaning cartridges: AutoClean and Manual. To choose Note: host-based cleaning, do not configure any cleaning slots, and configure your host application to manage cleaning tape drives. Configuring cleaning slots on the library may affect the host application. Media The screen includes information about the number of empty cleaning slots in the library. If two or more cleaning slots are configured and have cleaning tapes in them, the library chooses which cleaning tape to use.If you do not perform a shutdown before you physically. In order for Encryption the library to know the encryption state, the tape must have been placed into an encryption-capable tape drive in the library. This can help you allocate your tape drive resources properly. If more than one tape drive resided in that location during the selected range, then the attribute values for all the tape drives that resided in that location are combined in the chart. Select in any combination, including all (default) and none. If you select no attributes, the chart displays the TapeAlert count for the selected Grouping. You can save up to 20 templates for each type of advanced report. There may be times when you will need to upgrade your library and tape drive firmware as directed by Quantum Technical Support.Verify with the release notes or Quantum Technical Support that you are updating the library with the correct version of firmware. For technical support contact information, see Getting More Information or Help Library firmware version 200G.GSxxx and 210G.GSxxx (SP1) support. The web client allows you to upgrade tape drive firmware using a firmware image file.

    If you need to downgrade LTO-4 tape drive firmware from level 82FB or higher to level 77BE or lower, contact Quantum Technical Support for instructions and assistance.For technical support contact information, More Information or Help on page 8. Adding, removing, or replacing library components may require you to power off the entire library. There are a few components, however, that you can service without powering off the library, such as replacing tape drives. See Library in a Rack on page 284 for instructions. The instructions include procedures for removing and replacing tape drives. 2 Connect the SCSI cables to the tape drives. The module terminator is not the same as a SCSI Caution: terminator. Using a SCSI terminator instead of a module terminator will damage the library.All libraries taller than 14U must be installed in a rack Warning: having a main protective earthing (grounding) terminal,. See Library in a Rack on page 284 for instructions. The instructions include procedures for removing and replacing tape drives. 2 Connect one end of the SAS cable to the tape drive. Connect the other end of the SAS cable to the host. Cable Management Guidelines Configuring Your Library on page 47. Blue hook-and-loop fastener —Secures Ethernet cables to expansion modules. Push-in clip — to secure hook-and-loop fasteners to expansion modules. M5 thumbscrew — For older library models without drilled holes for push-in clips. The adhesive-backed wire saddle clamp secures Ethernet cables to the control module. Power cord management is important especially for the larger, expanded library configurations. Do not plug the cord into power source until you are ready to power on the library. Cable Management Guidelines. See Installing the Library in a Rack instructions on installing a rack-mount kit. Lifting the robot by the thin metal rod will bend the rod.Before removing the control module’s bottom cover Caution: plate, the robot assembly must be parked as described Step 4 above.

    Otherwise, the guide pin may scratch the front doors of the module beneath it. Replacing an Expansion Module. Then lower the module’s guide pin (located at the base of the front of the module) by. Scalar i500 User’s Guide. If a gap exists, the library cannot mechanically initialize. 9 Unpark the robot assembly. For details, see Removing, and Replacing Tape Drives 3 Add the power supplies. If you did not save a recent configuration, you may need to manually restore your settings. The LCB will fit snugly into its slot. Save the cover plate in case the redundant power supply needs to be removed at a later date. The two green LEDs should be solidly lit, and the blue LED should be off. All Scalar i500 libraries taller than 14U must be installed in a rack. The rack secures the bottom module, and all other modules are then secured to the bottom module. The rackmount kit allows you to secure the bottom module in the rack. Different racks require different rackmount parts. Although the rackmount kit contains many parts, the parts you use depend on your rack’s mounting holes. Secure the rack tightly, so that the ferrule fits snugly within the hole in the rack.Some thumbnuts may have loosened during installation. The thumbscrews should thread through the holes in the rack shelves and fasten completely and evenly. 4 Install the left rack ear.Notice that each rack unit, as delineated by the alignment markers in the rack, contains three mounting holes. If you are adding a module anywhere above the control module, position the nut clip (or cage nut) at the middle hole in that unit. The thumbscrews should thread through the nut clips (or cage nuts) and fasten completely and evenly. Scalar i500 User’s Guide. Scalar i500 User’s Guide. Newly added tape drives need to be installed and verified one Note: at a time. Firmware downloads may take about 15 minutes. 7 Check the tape drive’s LEDs to make sure that the drive functions correctly. If you do not configure control.

    The status LEDs must be at the bottom. You will feel the blade pins connect with the expansion module’s backplane as the blade locks into place.It is recommended that you use the original shipping carton and packaging materials to further protect your library. Without tape drives, tape cartridges, or power Warning: supplies, a control module weighs approximately 58 lbs. An expansion module, without tape drives, tape cartridges, or power supplies, exceeds 65 lbs. It provides you with status information about various library subsystems and components. It also notifies you of issues it detects and guides you through diagnosing and correcting issues before problems interfere with backups. Access the library’s online Help system if you have questions about the instructions provided. Others must be resolved by Service personnel. Only one person at a time can resolve a ticket. The screen refreshes, with the Tickets for all closed RAS tickets. Be careful when pressing the Caution: closes all RAS tickets even if they are not resolved. If you updated the library firmware since last saving the configuration, the library automatically restores the library firmware to the version that was saved with the configuration. When the robot has finished calibrating, the “Library Not Ready”. The LEDs blink 10 times per second for one minute. Tape drive log information can be used to help troubleshoot library and tape drive issues. You can use the appropriate tape drive. Tape drive sled log information can be used to help troubleshoot library, tape drive sled, and tape drive issues. You can use the the appropriate tape drive sled. LEDs can sometimes communicate that a problem exists when RAS tickets cannot. For example, an LED can indicate a firmware problem that prohibits the library from generating RAS tickets. By observing the blinking pattern of LEDs on tape drives, however, you can discern which operation the tape drive is currently performing.

    Examples of such library service actions include installing a new library or replacing a FRU or CRU. It also scans the top and bottom-most slots in the library. Time required to complete the Tour is five minutes per module. Make your choice and select Next The IVT test cannot be performed from the web client.If the external and internal network settings are the same, the web client cannot connect to the library. Be sure any crucial operations have stopped before you enter Diagnostics. See Diagnostics on page 352 for more information. Click Progress Window. You can access the screen, but you cannot apply changes while another administrative user is performing the same operation.The data will be overwritten on the suspect cartridge. When working with tape cartridges, certain considerations should be taken into account. For example, all tape cartridges in the library must have a barcode label. Before loading a cartridge into the library, make sure that the write-protect switch is positioned correctly (either on or off). Quantum-supplied barcode labels provide the best results.Most manufacturers offer cartridges with the labels already applied or with the labels included that you can attach. The Scalar i500 library supports the following components.Slot counts in this User’s Guide do not include five inaccessible Note: slots in the bottom row of any library configuration. For more. Temperature ranges apply to product inlet temperatures, not Note: necessarily to ambient room temperatures. Airflow restrictions or other heat-generating equipment within the rack enclosure may cause a rise over ambient room temperatures. Component Drive Sled Power Supply Robot 5U Chassis (empty) 9U Chassis (empty) 5U Package Kit. This section provides information about TapeAlert flags, including the identifying number, severity, recommended message, and probable cause. No data has been lost, but there has been a reduction in the performance of the tape.

    A redundant interface port on the tape drive has failed. A tape drive cooling fan has failed. Run extended diagnostics to verify and diagnose the problem. Check the tape drive user’s manual for device- specific instructions on running extended diagnostic tests. Scalar i500 User’s Guide Recommended Application Client Message. A serial bus network of microcontrollers A tape used to clean recording heads A method of interfacing with a file system. A value or setting that is selected by the hardware or software Default unless specified otherwise by the user. DHCP (Dynamic Host Configuration Protocol) dynamic IP addresses to devices on a network. In the Scalar i500 tape library, a “fiducial tab” refers to the plastic locator tabs which are installed on the media storage columns. The medium changer (robot) determines the location of these tabs to identify media storage locations. Gb E or GigE (Gigabit Ethernet) transmitting data across traditional LANs. GigE is an enhanced version of the Ethernet protocol that has been used for many years as the underlying transport technology in IP networks. A LUN can be an end user, a file, or an application. In storage technology, a single large storage device might be divided into smaller pieces, either to make the vast storage space more manageable or. When the storage space is divided into smaller parts, each part is configured with its own SCSI unique identifier, or LUN. A container for removable media storage used in tape Magazine libraries. A material that stores data, such as tapes in cartridges or optical Media disks. When possible, a RAS ticket provides instructions for resolving the issue. A RAS attribute that is designed to prevent failure of a storage Reliability solution. See also RAS. An appliance containing data that can be accessed, added Storage device to, changed, or deleted by the user. The storage media types An address on a An industry The protocol governing.

    A storage device can be a single disk drive, or constitute thousands of tapes in a large tape library. The physical home where a data cartridge resides. Storage slot A feature that provides predictive alerts, warning of. The world wide name is integral to Fibre Channel operations. WWPN (World Wide Port Name) address for each port on an FC-connected device. It is used to identify available SAN devices at end points. We have 14 Quantum Scalar i500 manuals available for free PDF download: User Manual, Reference Manual, Getting Started Manual, Quick Start Manual, Installation Manual, Release Notes, Instructions Manual, Warranty, Upgrade Instructions, Unpacking Instructions Remote Authentication. Scalar i500A, October 2008, Made in USA. Quantum Corporation provides this publication “as is” without. Page 3: Contents Contents. Preface 1. Chapter 1 Description 9Page 5 Changing Partition Modes. 69Page 6 Viewing FC Host Information. 107Chapter 5 Getting Information 147Page 11 Glossary 382. Scalar i500 User’s Guide xiPage 14: Figures FiguresPage 15 Figure 17 Multi-Module SCSI Cabling. 174Audience This guide is intended for anyone interested in learning about or anyonePage 17 PrefacePage 18 Preface. Mercury StatementPage 19 PrefaceDisposal of Electrical and. Electronic EquipmentRelated Documents Documents related to the Scalar i500 are shown below. The documentsPage 22 PrefacePage 23 PrefacePage 26 Chapter 1 Description. Figure 2 14U Library. Configuration (5U Control. Module Plus One 9U. Expansion Module)Figure 3 23U Library. Module Plus Two 9U Expansion. Modules)ModulesFront Panel ComponentsPage 32 Chapter 1 DescriptionPage 33 Chapter 1 DescriptionFor more information on the library userFigure 6 Back Panel. ComponentsLibrary Control Blade 1 The library control blade (LCB) manages the entire library. Page 38 Chapter 1 DescriptionFigure 8 Library Control BladeRobotic System.